Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Band Pass Filter				
			 
			
							
										
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-40.0/+80.0 degrees celsius					
				 
							
					
						MRC:
						The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
					 
					
						Average Life Rating In Hours:
					
					
						20000.0					
				 
							
					
						MRC:
						The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
					 
					
						Reference Frequency Per Function:
					
					
						960.0 hertz blank					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						100.0 kilohms blank					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						100.0 kilohms blank					
				 
							
					
						MRC:
						The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
					 
					
						Input Impedance Per Function W/load:
					
					
						100.0 kilohms blank					
				 
							
					
						MRC:
						The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
					 
					
						Output Impedance Per Function W/source Across Input:
					
					
						100.0 kilohms blank					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
					 
					
						Insertion Loss At Reference Frequency Per Function In Decibels:
					
					
						6.0 blank					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 pin input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						2 pin output 2nd function