Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						222-10nb13-2222715					
 
					
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Hand reset
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pressure Switch				
			 
			
										
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Watertight and dustproof					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						10.812 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.375 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the horizontal plane.AFDS
					 
					
						Longest Horizontal Distance Between Mounting Centers:
					
					
						4.000 inches 					
				 
							
					
						MRC:
						The longest distance between mounting centers parallel to the vertical plane.AFDV
					 
					
						Longest Vertical Distance Between Mounting Centers:
					
					
						3.000 inches 					
				 
							
					
						MRC:
						The shortest distance between mounting centers parallel to the vertical plane.AFDW
					 
					
						Shortest Vertical Distance Between Mounting Centers:
					
					
						1.062 inches 					
				 
							
					
						MRC:
						The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
					 
					
						Pressure Switch Type:
					
					
						Gage					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Bracket and unthreaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Electrical access port					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Increase					
				 
							
					
						MRC:
						The maximum pressure that an item will withstand without resulting in any permanent changes in the structural,mechanical,or electrical characteristics.CQJB
					 
					
						Proof Pressure:
					
					
						5600.00 pounds per square inch gage					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Isosceles triangle					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole,  single throw,  both positions maintained					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Screw					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						16.0 amperes inductive load first voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						2.0 amperes inductive load fourth voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						3.2 amperes inductive load second voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						9.6 amperes inductive load third voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point adjustable					
				 
							
					
						MRC:
						The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
					 
					
						Contact Adjustment Range:
					
					
						+500.00/+5000.00 actuation point pounds per square inch gage					
				 
							
					
						MRC:
						Indicates the type of device provided for manual adjustment of the contact(s).CTYS
					 
					
						Contact Adjustment Type:
					
					
						Internal actuation point hex nut with scale					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						115.0 ac at sea level first voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						115.0 dc at sea level third voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						550.0 ac at sea level second voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						550.0 dc at sea level fourth voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Gas or liquid					
				 
							
					
						MRC:
						An indication of the precious material and its location in the item.PMLC
					 
					
						Precious Material And Location:
					
					
						Contacts silver					
				 
							
					
						MRC:
						Identification of the precious material contained in the item.PRMT
					 
					
						Precious Material:
					
					
						Silver