Teilenummer 2225-1R

Oscilloscope

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
2225-1r
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
013180368
NSN
Nationale Bestandsnummer:
6625-01-318-0368 6625013180368
TXT
Beschreibung:
Oscilloscope
INC
INC
Artikelname-Code:
00357
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
17.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
15.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 440.0 hertz
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Perform measurements associated with dual time base scopes
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 95.0 volts and 250.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
2
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
An indication of whether or not a generator driven feature is included.BGQM
Generator Driven Feature:
Not included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal and vertical
MRC:
The range of complete cyclic changes,per unit of time,for which the sweep is rated.BGQP
Sweep Frequency Range:
+5.0/+50.0 megahertz
MRC:
The length of time consumed by a single trigger sweep.BGQQ
Single Trigger Sweep Duration:
7.0 nanoseconds
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Not provided
MRC:
The minimum and maximum frequencies to which the x-axis will respond.BHDQ
X-axis Frequency Response Rating:
2.0 megahertz
MRC:
The minimum and maximum frequencies to which the y-axis will respond.BHDR
Y-axis Frequency Response Rating:
Between 40.0 megahertz and 50.0 megahertz
MRC:
The minimum and maximum frequencies to which the z-axis will respond.BHDS
Z-axis Frequency Response Rating:
5.0 megahertz
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Not provided
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Not included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
The value,or range of values,for which the viewing screen is rated.BHFQ
Viewing Screen Voltage Rating:
12.6 kilovolts
MRC:
An indication of whether or not trace erasing provisions are provided.BHFR
Trace Erasing Provision:
Not provided
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Not provided
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Hf/lf reject trigger filters; x5, x10, x50 magnification; peak to peak auto triggering; two channel, single time base

Ähnlich Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken