Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pulse Transformer				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.469 inches 					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
					 
					
						Impedance Rating In Ohms:
					
					
						47000.0  single component single secondary					
				 
							
					
						MRC:
						The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
					 
					
						Impedance Rating In Ohms:
					
					
						10000.0  single component single primary					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
					 
					
						Body Outside Diameter:
					
					
						1.625 inches 					
				 
							
					
						MRC:
						The distance between mounting facility centers.AEJN
					 
					
						Distance Between Mounting Facility Centers:
					
					
						1.188 inches  single mounting facility single center group					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						2 single group					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Threaded stud single group					
				 
							
					
						MRC:
						The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
					 
					
						Winding Function And Quantity:
					
					
						1 primary single component and 1 secondary single component					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						32 single group					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.138 inches single group					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Unc single group					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						4 solder stud