Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Output term covers
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply Assembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Rack adapter nsn 6130-01-162-5959model lra-15; power supply nsn 6130-01-084-3246 model lns-y-5-ov; power supply model lns-x-28-42769; (2) power supplies 6130-01-138-1685 model lns-y-15 (2) overvoltage protector 5962-01-087-2308 model l-6-ov-15; overvoltage protector 5920-01-097-7526 model l-12-ov-28
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/fps-11 (v)
MRC:
The commercial and government entity (cage) code of the government agency,industrial organization,or other source,which controls the document.AJJY
Document Source:
80103
MRC:
The number or symbol used to identify the document.AJKA
Document Identification:
23211
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of power unit included with the item.AMKG
Power Unit Type:
Silicon controlled rectifier single operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
210.0 ac pounds per hour dry 1st alternate operating power rqmt and 254.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 2nd alternate operating power rqmt and 127.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
14.2 dc volts 3rd power output and 15.7 dc volts 3rd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
14.2 dc volts 2nd power output and 15.7 dc volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.7 dc volts 1st power output and 27.3 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
4.7 dc volts 4th power output and 5.2 dc volts 4th power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 440.0 hertz single operating power rqmt
MRC:
The name of the government agency or commercial organization that controls the component.AQHK
Component Controlling Agency:
Lambda elect
MRC:
The name of the component assigned by the controlling agency.AQHL
Component Name:
Power supply assembly
MRC:
The specific number used to identify the component.AQHM
Component Identifying Number:
23211 drawing no.
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-0.0/+71.0 degrees celsius
MRC:
The number of power units provided.BGQF
Power Unit Quantity:
4
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
On-off switch-indicator and digital ammeter and digital voltmeter and remote error sensing capability and voltage adjustment and over voltage protector and over current protector and fuse and input to output isolation and input to case isolation and output to case isolation and over temperature protection
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 dc amperes 2nd power output and 3.4 dc amperes 2nd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 dc amperes 3rd power output and 3.4 dc amperes 3rd power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.4 dc amperes 1st power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.1 dc amperes 4th power output and 6.0 dc amperes 4th power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
8 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection