Tpower supplies used are p/n lrs- 53-5 nsn 6130-01-233-0139 q type 1; p/n lrs-56-24 q type 2; p/n lra-15-cs rack adapter w/chassis slides; front panel perconfiguration 4 q type 1; p/n pc-1 pot covers q type 3; top cove (perforated metal) q type 1
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply Assembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Fungus proof
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
C-141 main trainer
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of power unit included with the item.AMKG
Power Unit Type:
Silicon controlled rectifier single operating power rqmt
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack or slide support
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
187.0 ac pounds per hour dry 1st alternate operating power rqmt and 265.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt95.0 ac pounds per hour dry 2nd alternate operating power rqmt and 132.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 1st power output5.0 dc volts 2nd power output-24.0 dc volts 3rd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 440.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-10.0/+71.0 degrees celsius
MRC:
The number of power units provided.BGQF
Power Unit Quantity:
3
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Dc ammeter and dc voltmeter and ground wire terminal and over temperature protection and over voltage protector and remote control and remote error sensing capability and voltage adjustment
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
20.0 dc amperes multiple power outputs w/identical ratings
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
6 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip single power output
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature: