Teilenummer 240-2677-200

Reactor

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
240-2677-200
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
004363938
NSN
Nationale Bestandsnummer:
5950-00-436-3938 5950004363938
TXT
Beschreibung:
Reactor
INC
INC
Artikelname-Code:
00724
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Fixed
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
30.00 millihenries single component single winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.390 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.320 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.355 inches
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
20.0 milliamperes dc single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
72.000 single component single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 wire lead

Ähnlich Reactors

« Coils and Transformers {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken