Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Relay-switch
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Plastic
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.200 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.200 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the type of action provided.AMWM
Action Type:
Time delay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Time delay
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Ac
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 102.0 and 132.0
MRC:
The amount of operating current,expressed in amperes.APHB
Operating Current In Amps:
75.0
MRC:
The designation that identifies the schematic diagram of the electrical configuration of a switch.APLQ
Switch Contact Arrangement:
2spdt
MRC:
The maximum voltage rating at which the contact is rated,expressed in volts.APLS
Contact Maximum Voltage Rating In Volts:
600.0
MRC:
The amount of current at maximum rated voltage for which the contact/s/ is designed.APLT
Contact Current Rating At Maximum Rated Voltage:
5.0 amperes
MRC:
The maximum amount of current the contact/s/ will accommodate.APLW
Contact Maximum Rated Current:
20.0 amperes resistive
MRC:
An indication of the amount of voltage for which the contact/s/ is designed to withstand at the maximum rated current.APLX
Contact Voltage Rating At Maximum Rated Current:
240.0
MRC:
The alternating current voltage of the continuous load.APLZ
Err Default:
Err default and err default
MRC:
The alternating current voltage of the continuous load.APLZ
Continuous Load Ac Voltage:
Between 120.0 volts and 240.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which the item is rated.APMA
Err Default:
Err default
MRC:
The number of complete cyclic changes,per unit of time,for which the item is rated.APMA
Continuous Load Frequency Rating:
60.0 hertz
MRC:
The alternating current rating of the continuous load.APMB
Err Default:
Err default
MRC:
The alternating current rating of the continuous load.APMB
Continuous Load Ac Current Rating:
10.0 amperes
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Err Default:
Err default
MRC:
The value/s/,or range of values,of direct current potential for which the continuous load is rated.APMC
Continuous Load Dc Voltage Rating:
30.0 volts
MRC:
The direct current rating of the continuous load.APMD
Err Default:
Err default
MRC:
The direct current rating of the continuous load.APMD
Continuous Load Dc Current Rating:
15.0 amperes
MRC:
Indicates the type of tripping action used by the item.APMJ
Err Default:
Err default
MRC:
Indicates the type of tripping action used by the item.APMJ
Trip Type:
Trip free