Teilenummer 2465CTS

Oscilloscope

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
2465cts
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
015480120

Informationen zum Teil
Four channel oscilloscope

NSN
Nationale Bestandsnummer:
6625-01-548-0120 6625015480120
TXT
Beschreibung:
Oscilloscope
INC
INC
Artikelname-Code:
00357
INC
COM
Beachtung:
MRC:
Indicates the designed use of the item.ALCD
Usage Design:
Faster and more precise measurements in a portable oscilloscope; automatically measuring frequency, period pulse width, and time between events; for moderate speed signals risetimes and falltimes can be automatically measured; includes gpib ieee standard 488 prammable for semiautomatic measurement systems, 150 mhz counter/timer/trigger, ctt, with 17-bit word recognizer and two additional p6131 probes
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Included
MRC:
Indicates the type of sweep circuits provided.BGQN
Sweep Circuit Type:
Horizontal
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Ambient temp operating m 15.0 to p 55.0 degrees c; nonoperating m 62.0 to p85.0 degrees c; altitude operating to 4600 m; operating temp decreases 1deg c for each 1000 ft above 5000 ft; nonoperating to 15000 m; vibration operating 15 minutes along each of three axes at a total displacement of 0.025 inch p-p with frequency varied from 10 hz to 55 hz in one-minute sweeps; humidity operating and nonoperating stored at 95 pct relative humidity for 5 cycles from p30.0 to p 60.0 degrees c with operational performance checks at p30.0 and p55.0 degrees c; shock operating and nonoperating 50 gs, half-sine, 11 ms duration, three shocks on each face, for a total of 18 shocks; meets mil-g-28800c environmental requirements for type iii, class 3, style c equipment

Ähnlich Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken