Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						247asc0105-001					
 
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pulse Generator				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						1.423 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.312 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+5.0/+55.0					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						+5.0 to 55.0					
				 
							
					
						MRC:
						The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
					 
					
						Shock Resistance Rating In Gravitational Units:
					
					
						20.0					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+75.0 degrees celsius					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0 to 75.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Sturgeon class ssn (637),  general purpose electronic test equipment (gpete),  los angeles class ssn (688),  versatile avionics shop test (vast) systems.					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Cylindrical					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						10000.0 feet					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Module					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						100.0 megahertz  input channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						12.4 gigahertz  3rd output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						0.0 gigahertz  1st output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						4.0 gigahertz  1st output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						4.0 gigahertz  2nd output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						8.0 gigahertz  3rd output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						8.0 gigahertz  2nd output channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						100.0 megahertz  input channel					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						8.0 gigahertz  2nd output channel					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						4.0 gigahertz  2nd output channel					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms output channel err-100					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms input channel err-100					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms input channel					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms output channel					
				 
							
					
						MRC:
						Indicates the type of signal data per channel.BHTZ
					 
					
						Signal Data Type Per Channel:
					
					
						Operating channel audio frequency					
				 
							
					
						MRC:
						The physical configuration of the output wave.BJBJ
					 
					
						Output Wave Shape:
					
					
						Sawtooth					
				 
							
					
						MRC:
						The length of time after impact that established the condition at which the shock resistance rating applies.BJBN
					 
					
						Shock Pulse Duration Time:
					
					
						1.0 milliseconds					
				 
							
					
						MRC:
						Indicates the type of connection and its location on the item.BJBP
					 
					
						Connection Type And Location:
					
					
						Receptacle,  coaxial front and  receptacle,  coaxial rear					
				 
							
					
						MRC:
						The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
					 
					
						Fsc Application Data:
					
					
						Test set, elect. Equip.