Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Multimeter				
			 
			
										
					
						MRC:
						The type of electrical circuit in which the item is designed to be used.AACT
					 
					
						Circuit Current For Which Designed:
					
					
						Ac					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						8.875 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.875 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						8.500 inches 					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Digital display					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Bench					
				 
							
					
						MRC:
						The source of power which provides the energy required for the operation of the item.AWZJ
					 
					
						Power Source:
					
					
						External					
				 
							
					
						MRC:
						Indicates the type of display provided.BFQN
					 
					
						Display Type:
					
					
						Light emitting diode (l.E.D.).					
				 
							
					
						MRC:
						The number of digits displayed.BFQP
					 
					
						Display Digit Quantity:
					
					
						4-1/2					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.1 to 100.0 milliamperes,  ac single indicator 5th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.1 to 1000.0 milliamperes,  dc single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.1 to 1000.0 volts,  ac single indicator 2nd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.1 to 1000.0 volts,  dc single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+1.0 to 10000.0 kilohms single indicator 4th range					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Switch					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Portable and autoranging					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.03 pct i/p porm 1 lsd cmrr single indicator 1st range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.05 pct i/p porm 1 lsd single indicator 4th range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.1 pct i/p 1 lsd single indicator 3rd range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.2 pct i/p porm 2 lsd single indicator 2nd range					
				 
							
					
						MRC:
						The deviation from a standard or true value for which the item is rated.CTPT
					 
					
						Accuracy Rating:
					
					
						Porm 0.75 pct i/p porm 0.2 pct range single indicator 5th range					
				 
							
					
						MRC:
						The hue or tint of the display.CTQH
					 
					
						Display Color:
					
					
						Red single indicator single range					
				 
							
					
						MRC:
						The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
					 
					
						Circuit Attachment Method And Quantity:
					
					
						2 banana jack					
				 
							
					
						MRC:
						The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
					 
					
						Operating Voltage Rating In Volts:
					
					
						Between 105.0 ac and 125.0 ac 					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Nonhardened					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Portable w/tilt view handle