Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Test set, alarm set
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electronic Circuit Plug Test Set
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
24.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
26.000 inches
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
Between 27.5 volts and 28.5 volts
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Connector adapter 3; extender cable assembly 1; dummy load assembly 1; cable assembly 1; case 1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Lgm-30 missile
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Test set, alarm set
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
An/gsm-31 (v) 2
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Alarm set
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to locate and isolate launch facility security system malfunctions to the drawer level in the cabinet and to the replaceable component level when the drawer monitoring selected signal sources. Confirms proper system operation after repair or replacement of components. Used to test the restricted area anti-intrusion alarm set an/fsq-14 (v) 2
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
12.800 inches
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
To 21m-lgm30f-4-1