Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Cleaned for use with liquid oxygen
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Solenoid Valve
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand all ends
MRC:
The length of a straight line which passes through the center of an aperture,and terminates at the circumference.ABVL
Aperture Diameter:
0.312 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Closed
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
232.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
G9 plain, optional en (pipe) all ends
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain, optional en (pipe) all ends
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal pipe all ends
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
50.0 pounds per square inch 2nd response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
60.0 pounds per square inch 1st response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches all ends
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
115.0 ac and 230.0 ac and 460.0 ac
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Stainless steel
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Air 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fuel/oil, hydrocarbon 3rd response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas, natural 2nd response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight thru
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt all ends
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
As differentiated by the cleaning process