Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Decks to be in phase within 1 pct, 1 watt at 221 degrees f
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Pre Wire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical servo mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 1.54200 inches and 1.56200 inches
MRC:
The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
Pilot Length:
Between 0.05700 inches and 0.06700 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.070 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.470 inches
First Flat Length:
Between 0.720 inches and 0.780 inches
Undercut Diameter:
1.620 inches
Undercut Width:
0.07300 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 1.690 inches and 1.750 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
Between 0.2494 inches and 0.2497 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
Between 1.410 inches and 1.470 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.600 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.220 inches
Mounting Lip Diameter:
Between 1.74500 inches and 1.75500 inches
Mounting Lip Depth:
Between 0.08800 inches and 0.09800 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round, v flatted
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
Between 294.0 and 306.0
MRC:
The maximum amount of turning force that can be applied through the operating shaft with0ut damage to the stops.AEFM
Maximum Stop Torque:
160.00 inch-ounces
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over more than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
2.000 percent, rated amperes c and better finish
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
2.000 percent, rated amperes c and better industrial clears
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
150.0 1st section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
150.0 2nd section
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
340.0
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-0.50/+0.50 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
1.25 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
Single section independent linearity
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
1 1st section
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
1 2nd section
MRC:
The limits of permissible variation from the rated value of the location of a tap per section.CRKS
Tap Location Tolerance Per Section:
-3.0/+3.0 degrees angular rotation all sections
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-2.0/+2.0 all sections
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Stops
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
Single section linear
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
85.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 turret