Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Niosh certified no. Tc23c-1938
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Gas-particulate Filter Unit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac or dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Papr) powered air purifying regulator systems
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
Any acceptable
MRC:
Indicates the type of filter used with the item.ALTR
Filter Type:
Combination gas-particulate
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Any acceptable
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
A measurement of the rate of filtration.BTLT
Filtration Rate:
50.000 cubic feet per minute
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the gas and particulate filter.CGSG
Err Default:
Err default
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the gas filter.CGSH
Err Default:
Err default
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the gas filter.CGSJ
Err Default:
Err default
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the gas and particulate filter.CGWZ
Err Default:
Err default
MRC:
The combined group of letters,numerals,and/or symbols which compose the assigned model number of the particulate filter.CGXB
Particulate Filter Model Number:
Any acceptable
MRC:
The specification and/or standard used to limit the element,compound,or mixture of the particulate filter.CGXC
Err Default:
Err default
MRC:
The individual protective device and the number the item is designed to accommodate.CGXF
Err Default:
Err default
MRC:
An indication of whether or not a headpiece is included.CGXH
Err Default:
Err default
MRC:
An indication of whether or not an air heater(s) is included.CGXJ
Err Default:
Err default
MRC:
The designed use of the blower assembly.CGXK
Blower Assembly Usage Design:
Indoor and outdoor
MRC:
An indication of whether or not a rain shield is required.CGXL
Rain Shield:
Not required
MRC:
An indication of whether or not an installation kit is included.CGXM
Installation Kit:
Not included
MRC:
An indication of whether or not a tool kit is included.CGXN
Tool Kit:
Not included
MRC:
An indication of whether or not provisions to suppress electromagnetic interference /emi/ are provided.CRFK
Electromagnetic Interference Suppression:
Not provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single