Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Coil				
			 
			
										
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						0.550 inches 					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Length:
					
					
						0.440 inches  single mounting facility single center group and 0.460 inches  single mounting facility single center group					
				 
							
					
						MRC:
						The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
					 
					
						Center To Center Distance Between Mounting Facilities Parallel To Width:
					
					
						0.165 inches  single mounting facility single center group and 0.185 inches  single mounting facility single center group					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						0.275 inches 					
				 
							
					
						MRC:
						The value(s) of inductance inherent in the item.ACYV
					 
					
						Inductance Rating:
					
					
						35.00 microhenries  single component single winding					
				 
							
					
						MRC:
						Indicates the type of support on which the coil is wound.ACZP
					 
					
						Coil Form Type:
					
					
						Solid single component					
				 
							
					
						MRC:
						The designation describing the method used in forming the core.ACZR
					 
					
						Core Construction:
					
					
						S0lid single component					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						0.600 inches 					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						115.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Plug-in single group					
				 
							
					
						MRC:
						The means by which the rating is determined.BKPL
					 
					
						Rating Method:
					
					
						Electrical single component single winding					
				 
							
					
						MRC:
						The amount of operating current for which the winding is designed.CRBZ
					 
					
						Winding Operating Current:
					
					
						1.75 amperes dc  single component single winding					
				 
							
					
						MRC:
						The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
					 
					
						Dc Resistance Rating In Ohms:
					
					
						0.053 single component single winding					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 pin