Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
2620-281assyca
Informationen zum Teil
First end id 0.379 in. Porm 0.001 in. To a depth of 0.313 in., second end od 0.375 in. And 0.562 in. From end
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Metallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.500 inches
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.688 inches
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
5.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the inner conveying tube.ADJL
Inner Conveying Tube Style:
Annular close-pitch corrugated
MRC:
The hue or tint of the exterior of the item.ADJS
Exterior Color:
Natural
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded external tube 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded external tube 2nd end
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
2800.0 pounds per square inch
MRC:
The material and formation identifying the structural characteristic/s/ of the item and location.CQCS
Layer Composition And Location:
Outer layer braided bronze wire
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
150.0 pounds per square inch
MRC:
A steady,uniform,internal,static pressure that the item must withstand without leakage,abnormal distortion,or damage.CRDW
Hydrostatic Test Pressure:
300.0 pounds per square inch
MRC:
The ultimate maximum vacuum,expressed in terms of absolute pressure,that may be produced by or applied to an item.CRSM
Vacuum In Torr:
25.4
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
15.800 inches
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.500 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.625 inches 1st end
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
80064-845-1889636 rev-b assembly aa drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)