Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Electrostatic shield brought out to terminal six
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Band Pass Filter
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.230 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.410 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.950 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+10.0/+500.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+65.0 degrees celsius
MRC:
The numeric value indicating the average life expectancy for which the item is rated,expressed in hours.AFSV
Average Life Rating In Hours:
10000.0
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
425.0 single high pass pulses per second
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
425.0 single high pass two phase to three phase
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
425.0 single high pass two phase to two phase
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
600.0 ohms 1st band pass
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
600.0 ohms 2nd band pass
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
600.0 ohms 3rd band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
600.0 ohms 1st band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
600.0 ohms 2nd band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
600.0 ohms 3rd band pass
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band pass 1st function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd band pass 2nd function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd band pass 3rd function
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded stud
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrostatic shield
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 3rd band pass
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band pass
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 turret ground 3rd function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 turret input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 turret output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
382.50 hertz 2nd band pass 2nd function and 403.75 hertz 2nd band pass 2nd function and 446.25 hertz 2nd band pass 2nd function and 467.50 hertz 2nd band pass 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
382.50 hertz 1st band pass 1st function and 403.75 hertz 1st band pass 1st function and 446.25 hertz 1st band pass 1st function and 467.50 hertz 1st band pass 1st function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
382.50 hertz 3rd band pass 3rd function and 403.75 hertz 3rd band pass 3rd function and 446.25 hertz 3rd band pass 3rd function and 467.50 hertz 3rd band pass 3rd function
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
403.75 hertz 1st band pass and 446.25 hertz 1st band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
403.75 hertz 2nd band pass and 446.25 hertz 2nd band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
403.75 hertz 3rd band pass and 446.25 hertz 3rd band pass
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band pass 1st function and 30.0 1st band pass 1st function
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 2nd band pass 2nd function and 30.0 2nd band pass 2nd function
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 3rd band pass 3rd function and 30.0 3rd band pass 3rd function
MRC:
The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CRDC
Maximum Dielectric Withstanding Dc Voltage:
500.0 volts at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on one surface