Teilenummer 263-1AX4

Electromagnetic Relay

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
263-1ax4
Entmilitarisierung:
No
Lagerfähigkeit:
Maßeinheit:
NIIN:
009294606
NSN
Nationale Bestandsnummer:
5945-00-929-4606 5945009294606
TXT
Beschreibung:
Electromagnetic Relay
INC
INC
Artikelname-Code:
32512
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.370 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.370 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetic
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1
MRC:
The number of coils included on the item.APCN
Coil Quantity:
1
MRC:
The measured opposition to the flow of direct current offered by the item winding.APNA
Winding Dc Resistance Rating:
1.15 kilohms single winding
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Inert gas
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 plug-in terminal single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Polarized
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
Nonpile-up Main Contact Arrangement:
1 pole, single throw, normally open, momentary action
MRC:
The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
Operating Voltage Rating And Type At Specificationified Temp:
20.0 volts dc 25 degrees celsius single winding
MRC:
The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
Main Contact Load Current Rating At Maximum Rated Voltage:
50.0 milliamperes dc resistive load
MRC:
The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
Main Contact Maximum Voltage Rating In Volts:
250.0 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 pin all functions

Ähnlich Electromagnetic Relaies

« Relays and Solenoids {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken