						Informationen zum Teil
						Contacts open on pressure increase. Close on temperature increase
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pressure-thermostatic Switch				
			 
			
										
					
						MRC:
						A measurement of the longest dimension of a capillary tube.AEVT
					 
					
						Capillary Tube Length:
					
					
						32.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bulb.AEVU
					 
					
						Bulb Length:
					
					
						1.750 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
					 
					
						Bulb Diameter:
					
					
						0.688 inches 					
				 
							
					
						MRC:
						The general classification of a pressure switch based on the reference method used to measure the sensed pressure.AJZC
					 
					
						Pressure Switch Type:
					
					
						Gage					
				 
							
					
						MRC:
						Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
					 
					
						Tempurature Sensing Element Type:
					
					
						Capillary tube-bulb					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Base					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						2 pole,  single throw,  both positions maintained					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Tab w/screw					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						0.250 milliamperes resistive load single voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Actuation point adjustable,  preset					
				 
							
					
						MRC:
						The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
					 
					
						Contact Adjustment Range:
					
					
						+5.00/+225.00 actuation point pounds per square inch					
				 
							
					
						MRC:
						Indicates the type of device provided for manual adjustment of the contact(s).CTYS
					 
					
						Contact Adjustment Type:
					
					
						External actuation point knob					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						28.0 dc at sea level single voltage