Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
270-2207-010
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electronic Control Amplifier
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.187 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.750 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.500 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
General purpose
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-25.0/+85.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
A designation assigned to the item for purpose of ready identification.AJKH
Identification Designator:
D12-4-2-19645
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The number of switching cycles that occur per second.BHSY
Switching Rate Per Second:
10000
MRC:
The shift of the frequency of the item.BHSZ
Frequency Shift:
10.0 kilohertz
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 kilohertz output channel
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Continuous
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
6.0
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
7.0 milliwatts input
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
15.000 volts input
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Operating channel servo
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
1 light
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Solder lug bottom
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
60.0 single voltage
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
10 solder lug external
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
15.0 single voltage
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Automatic gain control
MRC:
The number of alternating current phases.FAAZ
Phase:
Single