Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
							
					
						Informationen zum Teil
						Ohms accuracy is porm 1 deg. Of arc; measures from neg. 20 to pos. 50 decibles
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Multimeter				
			 
			
										
					
						MRC:
						The type of electrical circuit in which the item is designed to be used.AACT
					 
					
						Circuit Current For Which Designed:
					
					
						Dc					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						3.125 inches 					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						7.000 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						5.250 inches 					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50 single indicator 1st range					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50 single indicator 3rd range					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50 single indicator 5th range					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50 single indicator 6th range					
				 
							
					
						MRC:
						The number of scale divisions.ABWG
					 
					
						Scale Division Quantity:
					
					
						50 single indicator 2nd range					
				 
							
					
						MRC:
						The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
					 
					
						Furnished Items And Quantity:
					
					
						Leads, test 2; batteries 2; manual 1					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Dial w/pointer					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Hand held					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator 1st range					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator 3rd range					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator 4th range					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator 5th range					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Black single indicator 6th range					
				 
							
					
						MRC:
						The hue or tint of the dial scale marking(s).APMM
					 
					
						Dial Scale Marking Color:
					
					
						Red single indicator 2nd range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25/+1.25 at full scale single indicator 1st range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25/+1.25 at full scale single indicator 3rd range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25/+1.25 at full scale single indicator 5th range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-2.0 to 2.0 at full scale single indicator 2nd range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-0.75 to 0.75 at full scale single indicator 6th range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.0 to 1.0 at full scale single indicator 4th range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25 to 1.25 at full scale single indicator 1st range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25 to 1.25 at full scale single indicator 3rd range					
				 
							
					
						MRC:
						An indication of the accuracy of an item,expressed in percent.APPN
					 
					
						Accuracy In Percent:
					
					
						-1.25 to 1.25 at full scale single indicator 5th range					
				 
							
					
						MRC:
						The hue or tint of the background.AQFY
					 
					
						Background Color:
					
					
						White single indicator all ranges					
				 
							
					
						MRC:
						The hue or tint of the pointer.ASSS
					 
					
						Pointer Color:
					
					
						Red single indicator all ranges					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator 1st range					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator 2nd range					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator 3rd range					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator 5th range					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Linear single indicator 6th range					
				 
							
					
						MRC:
						Indicates the type of graduations provided on the scale.BHDC
					 
					
						Scale Graduation Type:
					
					
						Nonlinear single indicator 4th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 20.0 megohms single indicator 4th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 50.0 microamperes,  dc single indicator 6th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+10.0 amperes,  dc single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+1000.0 volts,  dc single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 1000.0 volts,  ac single indicator 2nd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0/+500.0 milliamperes,  dc single indicator 5th range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 10.0 amperes,  dc single indicator 3rd range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 1000.0 volts,  dc single indicator 1st range					
				 
							
					
						MRC:
						The minimum to maximum value which the item is capable of measuring.BHMW
					 
					
						Measurement Range:
					
					
						+0.0 to 500.0 milliamperes,  dc single indicator 5th range					
				 
							
					
						MRC:
						The means provided for selecting a scale.BLSB
					 
					
						Scale Selection Method:
					
					
						Switch					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Portable					
				 
							
					
						MRC:
						The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
					 
					
						Circuit Attachment Method And Quantity:
					
					
						2 wire lead					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Plastic					
				 
							
					
						MRC:
						An indication of the nuclear hardness criticality of the item.NHCF
					 
					
						Nuclear Hardness Critical Feature:
					
					
						Nonhardened					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Portable