Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
274-0009-105
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Ceramic Diele Variable Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rotary
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.218 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.090 inches single shaft
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.030 inches single shaft
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.145 inches
MRC:
The center to center distance between terminals parallel to the diameter of the item.AEBS
Center To Center Distance Between Terminals Parallel To Diameter:
0.205 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encapsulated
MRC:
The torque required for the adjustment device.AXGR
Adjustment Device Torque:
Between 0.500 inch-ounces and 3.000 inch-ounces
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at 25 degrees celsius.AXGT
Insulation Dc Resistance At 25 Deg Celsius:
10.0 gigohms
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 terminal
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -55.0 degrees celsius and 125.0 degrees celsius
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, slotted single shaft
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+2.5/+9.0 single section
MRC:
The minimum and maximum values of the electrical capacitance measured between two specified points on the item,expressed in picofarads.CTGN
Capacitance Range In Picofarads:
+2.5 to 9.0 single section
MRC:
The highest potential and type that may be applied to the item,at the highest operating temperature permissible without voltage derating.CTGP
Nonderated Voltage Rating And Type:
100.0 dc continuous single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
-4.50/+2.00 single section and -4.20/+3.40 single section
MRC:
The limits of capacitance change in percent at operating temperature from a stated value at 25 degrees celsius.CTGQ
Capacitance Change In Percent At Operating Tempurature From 25 Deg Celsius:
-4.50 to 2.00 and -4.20 to 3.40 single section
MRC:
Indicates the type and number of drive(s) provided for the adjustment device.CTGR
Adjustment Device Drive Type And Quantity:
1 shaft
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead