Primary-20kv, 2500 ohms impedance w/taps; secondary-50.0 ohms impedance w/12.5, 19.0, 25.0 and 38.0 ohms taps; corrosion and fungus resistant; electrostatic shielding shall be provided between primary and secondary windings

NSN
Nationale Bestandsnummer:
5950-01-490-0989 5950014900989
TXT
Beschreibung:
Radio Frequency Transformer
INC
INC
Artikelname-Code:
00777
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
23.500 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
40.0 kilohertz single component and 160.0 kilohertz single component
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
24.000 inches
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
8 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Foot single group and slot single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component