Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Two filtered functions
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Band Pass Filter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.090 inches and 3.100 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 2.940 inches and 2.950 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.050 inches and 1.060 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 0.740 inches and 0.760 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 0.940 inches and 0.960 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.410 inches and 0.430 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
147.5 single radio interference pulses per second
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
147.5 single radio interference two phase to two phase
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
147.5 kilohertz 2nd band pass 2nd function
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
1.0 kilohms 1st band pass
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
1.0 kilohms 2nd band pass
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
1.0 kilohms 2nd band pass 2nd function
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
68.0 kilohms 1st band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
68.0 kilohms 2nd band pass
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
68.0 kilohms 2nd band pass 2nd function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band pass 1st function
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd band pass 2nd function
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded stud
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Nut and shock resistant
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band pass
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 wire loop input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
2 wire loop output 2nd function
MRC:
The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
Maximum Dielectric Withstanding Ac Rms Voltage:
100.0 volts at sea level
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
143.00 kilohertz 2nd band pass 2nd function and 147.00 kilohertz 2nd band pass 2nd function and 148.00 kilohertz 2nd band pass 2nd function and 152.00 kilohertz 2nd band pass 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
143.00 kilohertz 1st band pass 1st function and 147.00 kilohertz 1st band pass 1st function and 148.00 kilohertz 1st band pass 1st function and 152.00 kilohertz 1st band pass 1st function
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
147.00 kilohertz 2nd band pass and 148.00 kilohertz 2nd band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
147.00 kilohertz 1st band pass and 148.00 kilohertz 1st band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
147.00 kilohertz 2nd band pass and 148.00 kilohertz 2nd band pass
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
147.00 kilohertz 1st band pass and 148.00 kilohertz 1st band pass
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band pass 1st function and 40.0 1st band pass 1st function
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 2nd band pass 2nd function and 40.0 2nd band pass 2nd function
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
0.123 pounds
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on opposite surfaces
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
10001-2234371 manufacturers specification control