Tubing wall construction can also be laminated
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b all flanges single connection facility
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand all flanges single connection facility
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 all bends e-plane
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.897 inches all flanges and 0.903 inches all flanges
Flange Inside Height:
0.397 inches all flanges and 0.403 inches all flanges
Flange Outside Width:
2.070 inches all flanges and 2.110 inches all flanges
Flange Outside Height:
1.570 inches all flanges and 1.610 inches all flanges
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.480 inches all flanges and 0.520 inches all flanges
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.07
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.03
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
10.0 pounds per square inch gage
Waveguide Outside Width:
1.000 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.164 inches all flanges single connection facility
Waveguide Inside Width:
0.900 inches
Waveguide Inside Height:
0.400 inches
Waveguide Outside Height:
0.500 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
8 threaded hole all flanges single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Contact type all flanges
Waveguide Leg Length:
1.230 inches
Waveguide Center To Center Distance:
Between 2.198 inches and 2.218 inches
Waveguide Height:
2.584 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy all flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy single tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film all flange inside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film single tubing segment inside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint all flange outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Paint single tubing segment outside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
U-bend type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all flanges single connection facility