Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Frequency Multiplier				
			 
			
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						5.000 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
					 
					
						Vibration Resistance Range In Hertz:
					
					
						Not rated					
				 
							
					
						MRC:
						The number of individual sections included in the item.AFBH
					 
					
						Individual Section Quantity:
					
					
						2					
				 
							
					
						MRC:
						The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
					 
					
						Shock Resistance Rating In Gravitational Units:
					
					
						Not rated					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						Not rated					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						An/usm-464					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						A designation assigned to the item for purpose of ready identification.AJKH
					 
					
						Identification Designator:
					
					
						292423p1-94117					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						Not rated					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Module					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						200.0 megahertz  input channel err-100					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						3.4 gigahertz  output channel err-100					
				 
							
					
						MRC:
						The decrease in strength of an electrical impulse,expressed in decibels.BHTH
					 
					
						Attenuation In Decibels:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The rated signal voltage for each channel.BHTK
					 
					
						Signal Voltage Rating Per Channel:
					
					
						Not rated					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						Not rated					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms output channel					
				 
							
					
						MRC:
						The maximum time an item will continuously run,expressed in hours.BJBM
					 
					
						Maximum Continuous Operating Time In Hours:
					
					
						Not rated					
				 
							
					
						MRC:
						A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
					 
					
						Reference Number Differentiating Characteristics:
					
					
						As differentiated by the source control drawing 292423