Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Ammeter
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
1.400 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.700 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
15 single indicator 1st range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
30 single indicator 2nd range
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
30 single indicator 3rd range
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Dial w/pointer
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator all ranges and red single indicator all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-3.0/+3.0 at full scale single indicator all ranges
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator all ranges
MRC:
The hue or tint of the pointer.ASSS
Pointer Color:
Black single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Linear single indicator all ranges
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+15.0 amperes, ac single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+30.0 amperes, ac single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+60.0 amperes, ac single indicator 3rd range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Clamp-on
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.