Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Check Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
225.0 degrees fahrenheit single response
MRC:
The minimum temperature at which the item is designed to operate.AEQJ
Minimum Operating Temp:
-65.0 degrees fahrenheit
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Horizontal
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 440c flow control device
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 630 body
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Ams5643 assn standard single material response body
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-s-763 federal specification single material response flow control device
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Passivate
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Mil-s-5002 military specification single treatment response