Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Degreaser				
			 
			
										
					
						MRC:
						An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
					 
					
						Inside Width:
					
					
						18.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest inside dimension of an item,in distinction from width.ADJU
					 
					
						Inside Length:
					
					
						32.000 inches 					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						125.0 degrees fahrenheit					
				 
							
					
						MRC:
						An inside measurement between specified points of an item,in distinction from height.AFEF
					 
					
						Inside Depth:
					
					
						15.000 inches 					
				 
							
					
						MRC:
						A numeric value which represents the number of devices that convert energy from one form to another.AKVR
					 
					
						Transducer Quantity:
					
					
						1					
				 
							
					
						MRC:
						The electrical voltage value for which the generator is rated.ALSP
					 
					
						Generator Voltage Rating:
					
					
						115.0					
				 
							
					
						MRC:
						The number of alternating current phases of the generator.ALSR
					 
					
						Generator Phase:
					
					
						Single					
				 
							
					
						MRC:
						The cycles per second (hertz) of the generator alternating current.ALSS
					 
					
						Generator Frequency Rating:
					
					
						60.0					
				 
							
					
						MRC:
						An indication of whether or not the item is portable.APCB
					 
					
						Portability:
					
					
						Nonportable					
				 
							
					
						MRC:
						Indicates the design type of the item.APGF
					 
					
						Design Type:
					
					
						Ultrasonic					
				 
							
					
						MRC:
						Indicates the type of current of the generator,whether alternating,direct,or both.BCPD
					 
					
						Generator Current Type:
					
					
						Ac					
				 
							
					
						MRC:
						An indication of whether or not an electric motor is included.BMWX
					 
					
						Electric Motor:
					
					
						Not included					
				 
							
					
						MRC:
						Indicates the capacity of the tank.BSSM
					 
					
						Tank Capacity:
					
					
						35.000 gallons					
				 
							
					
						MRC:
						The value of electrical input power for which the generator is rated.BWWR
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The value of electrical input power for which the generator is rated.BWWR
					 
					
						Generator Input Power Rating:
					
					
						115.000 volt-ampere					
				 
							
					
						MRC:
						The value of electrical output power for which the generator is rated.BWWS
					 
					
						Generator Output Power Rating:
					
					
						700.000 watts					
				 
							
					
						MRC:
						The range of complete cyclic changes,per unit of time,for which the generator output is rated.BWWT
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The range of complete cyclic changes,per unit of time,for which the generator output is rated.BWWT
					 
					
						Generator Output Frequency Range:
					
					
						+25.0 to 25.5 kilohertz					
				 
							
					
						MRC:
						The means by which the generator is cooled.BWWW
					 
					
						Generator Cooling Method:
					
					
						Any acceptable					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of the generator.BWWX
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of the generator.BWWX
					 
					
						Generatorheight:
					
					
						10.000 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of the generator,in distinction from thickness.BWWY
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of the generator,in distinction from thickness.BWWY
					 
					
						Generatorwidth:
					
					
						10.000 inches 					
				 
							
					
						MRC:
						An overall measurement between specified points of the generator,in distinction from height.BWWZ
					 
					
						Err Default:
					
					
						Err default					
				 
							
					
						MRC:
						An overall measurement between specified points of the generator,in distinction from height.BWWZ
					 
					
						Generatordepth:
					
					
						12.000 inches 					
				 
							
					
						MRC:
						An indication of whether or not a solvent reconditioner is included.BWXD
					 
					
						Solvent Reconditioner:
					
					
						Not included					
				 
							
					
						MRC:
						An indication of whether or not a spray cleaning provision is provided.BWXF
					 
					
						Spray Cleaning Provision:
					
					
						Provided					
				 
							
					
						MRC:
						An indication of whether or not an auxiliary solvent supply is included.BWXG
					 
					
						Auxiliary Solvent Supply:
					
					
						Not included