Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Rotary Compressor Unit				
			 
			
										
					
						MRC:
						The number of compressors incorporated in the unit.AAXG
					 
					
						Compressor Quantity:
					
					
						1					
				 
							
					
						MRC:
						The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
					 
					
						Duty Cycle In Percent:
					
					
						100					
				 
							
					
						MRC:
						The media the machine is designed to compress.AAXK
					 
					
						Gas For Which Designed:
					
					
						Air					
				 
							
					
						MRC:
						The rated capacity of gas delivered by the last stage of compression.AAXL
					 
					
						Discharge Flow Rate:
					
					
						2240.000 cubic feet per minute					
				 
							
					
						MRC:
						The gage pressure of gas delivered by the last stage of compression.  referred to as condensing pressure for refrigeration compressors.AAXM
					 
					
						Discharge Pressure:
					
					
						13.700 pounds per square inch gage					
				 
							
					
						MRC:
						The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
					 
					
						Cooling System Design:
					
					
						Mixed					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
					 
					
						Compressed Gas Cooling Medium:
					
					
						Fresh water					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the compressor.AAXR
					 
					
						Compressor Cooling Medium:
					
					
						Fresh water					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
					 
					
						Prime Mover Cooling Medium:
					
					
						Air					
				 
							
					
						MRC:
						The method by which a no load condition is obtained for starting the item.AAXV
					 
					
						Unloader Type:
					
					
						Automatic					
				 
							
					
						MRC:
						Indicates the type of mount utilized to support the item.AAXX
					 
					
						Mounting Type:
					
					
						Base					
				 
							
					
						MRC:
						The mechanical action by which compression takes place.AAYB
					 
					
						Rotary Compressor Design:
					
					
						Axial screw					
				 
							
					
						MRC:
						The number of stages incorporated in the item.AAYD
					 
					
						Stage Quantity:
					
					
						1					
				 
							
					
						MRC:
						The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
					 
					
						Compressor Speed At Rated Capacity In Rpm:
					
					
						3550.0					
				 
							
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of intake connection included on the item.AAYU
					 
					
						Intake Connection Type:
					
					
						Round flange					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of discharge connection included on the item.AAYW
					 
					
						Discharge Connection Type:
					
					
						Round flange					
				 
							
					
						MRC:
						Indicates the type of prime mover included with the unit.AKDJ
					 
					
						Prime Mover Type:
					
					
						Electric motor					
				 
							
					
						MRC:
						Indicates the type of control device provided.BDML
					 
					
						Control Device Type:
					
					
						Automatic start-stop					
				 
							
					
						MRC:
						Indicates the type of safety device(s) provided.BPRZ
					 
					
						Safety Device Type:
					
					
						Relief valve					
				 
							
					
						MRC:
						The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
					 
					
						Voltage In Volts And Current Type:
					
					
						460.0 ac					
				 
							
					
						MRC:
						The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
					 
					
						Brake Power Required:
					
					
						142.000 horsepower					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Three					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0