Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Module 1 is spdt recepeating
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Code Indicating Wheel Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.410 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.288 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.688 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.093 inches single mounting facility
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
10
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
6.075 inches single mounting facility
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
1.563 inches single mounting facility
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
H-3 sea king, h-2 seasprite, sh-60b lamps mark iii helicopters. C-130f hercules, ea-6b prowler, ta-4j, s-3b viking, p-3 orion aircraft.
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket single mounting facility and unthreaded hole single mounting facility
MRC:
Indicates the type of actuator provided.AYDW
Actuator Type:
Thumbwheel all actuators
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
28.0 dc at sea level
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular single mounting facility
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 10th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 2nd actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 3rd actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 4th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 5th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 6th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 7th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 8th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
10 9th actuator
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
8 1st actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Printed circuit
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
3.0 amperes resistive load dc at sea level
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 0, 1, 0, 1, 0, 1 1st section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 10th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 2nd section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 3rd section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 4th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 5th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 6th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 7th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 8th section
MRC:
An indication of the marking on the readout indicator.CTZF
Readout Indicator Marking:
0, 1, 2, 3, 4, 5, 6, 7, 8, 9 9th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 2nd section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 3rd section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 4th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 5th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 6th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 7th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 8th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 9th section
MRC:
An indication of the configuration of the coded contact switching structure.CTZT
Contact Arrangement Truth Table:
Bcd, 1 pole - 10 positions 10th section
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black each indicator background
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular inline indicating