Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.220 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.120 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetically sealed
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
30000.0 feet
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
13.5 dc pounds per hour dry 2nd operating power rqmt and 20.0 dc pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
14.5 ac pounds per hour dry 1st operating power rqmt and 35.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-55.0/+71.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1st power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2nd power output
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
100.0 dc milliamperes 1st operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
100.0 dc milliamperes 2nd operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Pin plug 1st operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Pin plug 2nd operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 1st operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 2nd operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Ambient air