Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Informationen zum Teil
Humidi type 5-95 pct non condensing; heat generating 25 btu hr; ac input load 100-240 v porm 10 pct
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Signal Data Converter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.650 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.430 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+32.0/+104.0 degrees fahrenheit
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
+21.0/+160.0 degrees fahrenheit
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Free-standing
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 hertz input channel and 60.0 hertz input channel
MRC:
The rated signal voltage for each channel.BHTK
Signal Voltage Rating Per Channel:
100.000 volts input and 240.000 volts input
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
0.05 amperes
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Converts between 10 base-t twisted pair and 10 base-fl, multi-mode or single-mode, fiber or 10 base-2 thin coax, 1u high, stand alone unit that includes diagnostic leds for each port and a universal, 100-240 vac, power supply