Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Power Supply				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						4.570 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						5.000 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						3.120 inches 					
				 
							
					
						MRC:
						The relationship of the electrical power source to the item.AKWC
					 
					
						Electrical Power Source Relationship:
					
					
						Operating					
				 
							
					
						MRC:
						The number of input alternating current phase(s).ANPM
					 
					
						Input Phase:
					
					
						Single single operating power rqmt					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						102.0 ac pounds per hour dry single operating power rqmt and 125.0 ac pounds per hour with retaining chain single operating power rqmt					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						15.0 dc volts  1st power output					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						-15.0 dc volts  2nd power output					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
					 
					
						Input Frequency Rating:
					
					
						47.0 hertz  single operating power rqmt and 420.0 hertz  single operating power rqmt					
				 
							
					
						MRC:
						The ambient temperature range at which the item is designed to operate.AYNH
					 
					
						Operating Ambient Tempurature Range:
					
					
						+0.1/+71.0 degrees celsius					
				 
							
					
						MRC:
						The number of output control(s) provided.BGHX
					 
					
						Output Control Quantity:
					
					
						1 1st power output					
				 
							
					
						MRC:
						The number of output control(s) provided.BGHX
					 
					
						Output Control Quantity:
					
					
						1 2nd power output					
				 
							
					
						MRC:
						Indicates the type of output control provided.BGHY
					 
					
						Output Control Type:
					
					
						Voltage adjustment 2nd power output					
				 
							
					
						MRC:
						Indicates the type of output control provided.BGHY
					 
					
						Output Control Type:
					
					
						Voltage adjustment 1st power output					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.CWGH
					 
					
						Output Current Rating:
					
					
						600.0 dc milliamperes  1st power output					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.CWGH
					 
					
						Output Current Rating:
					
					
						600.0 dc milliamperes  2nd power output					
				 
							
					
						MRC:
						The number of electrical output connections on the item.CWHF
					 
					
						Output Connection Quantity:
					
					
						2 2nd power output					
				 
							
					
						MRC:
						The number of electrical output connections on the item.CWHF
					 
					
						Output Connection Quantity:
					
					
						2 1st power output					
				 
							
					
						MRC:
						Indicates the type of electrical output connection.CWHJ
					 
					
						Output Connection Type:
					
					
						Ferrule 1st power output					
				 
							
					
						MRC:
						Indicates the type of electrical output connection.CWHJ
					 
					
						Output Connection Type:
					
					
						Ferrule 2nd power output