Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Radio Frequency Transmiss Switch				
			 
			
							
										
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Rectangular					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.970 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						2.670 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						1.090 inches 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.1 gigahertz  single frequency rf power handling and 12.4 gigahertz  single frequency rf power handling					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						0.1 gigahertz   and 12.4 gigahertz  single frequency rf power handling					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
					 
					
						Unthreaded Mounting Hole Diameter:
					
					
						0.203 inches 					
				 
							
					
						MRC:
						Indicates the type of switch included in the item.AEEA
					 
					
						Switch Type:
					
					
						Transfer					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-67.0/+185.0 degrees fahrenheit					
				 
							
					
						MRC:
						The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
					 
					
						Insertion Loss In Decibels:
					
					
						0.15 single					
				 
							
					
						MRC:
						A letter or group of letters used to designate the particular coaxial connector series.AHUC
					 
					
						Coaxial Connector Series Designation:
					
					
						N					
				 
							
					
						MRC:
						The design of the connector end.AHUD
					 
					
						Connector End Design:
					
					
						Female					
				 
							
					
						MRC:
						The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
					 
					
						Minimum Crosstalk Rating In Decibels:
					
					
						60.0 single					
				 
							
					
						MRC:
						The means provided for switching the actuator from one position to another.AKPC
					 
					
						Actuator Operating Method:
					
					
						Relay					
				 
							
					
						MRC:
						The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
					 
					
						Actuator Current Type And Rating In Amps:
					
					
						0.2 dc 					
				 
							
					
						MRC:
						The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
					 
					
						Actuator Voltage In Volts:
					
					
						28.0 					
				 
							
					
						MRC:
						An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
					 
					
						Switch Operation Sequence:
					
					
						Breaks before makes					
				 
							
					
						MRC:
						The time required for switching between any two adjacent positions.AKPP
					 
					
						Switching Time:
					
					
						20.0 milliseconds					
				 
							
					
						MRC:
						The number of coupling positions provided.AKRC
					 
					
						Coupling Position Quantity:
					
					
						3					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						2 unthreaded hole					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
					 
					
						Material:
					
					
						Aluminum body					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						94987-116099 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 tab,  solder lug and 3 receptacle,  coaxial