Teilenummer 308OPT01

Electronic Digital Data Analyzer

Preise und Verfügbarkeit

Reichen Sie dieses Formular ein, um die aktuellen Preise und die Verfügbarkeit dieser NSN zu erfahren.
Teilenummer:
Menge:
E-Mail-Adresse:
Telefon:
Referenz:
Firma:
Name:

Wir geben Ihre Daten nicht an Dritte weiter und verkaufen sie auch nicht.
Privatsphäre | Bedingungen

All major credit cards accepted as well as gov. p-cards
Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
308opt01
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
011087777

Informationen zum Teil
Mfg name-data analyzer

NSN
Nationale Bestandsnummer:
6625-01-108-7777 6625011087777
TXT
Beschreibung:
Electronic Digital Data Analyzer
INC
INC
Artikelname-Code:
46820
INC
COM
Beachtung:
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
13.900 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.610 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.300 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts and 220.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 48.0 hertz and 550.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
For use on ups system test and ajustments, ground wave emergency network (gwen) an/urc-117
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Cathode ray tube
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Provides timing, state, serial, signature analysis
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
20 megahz; portable; oper temp 0 to 50 deg. C; opt 01=p6406 word recognizer probe

Ähnlich Electronic Digital Data Analyzers

« Electrical and Electronic Properties Measuring and Testing Instruments {lang[catalog]}
Jetzt vergleichen»
Klar | Verstecken