Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
115/230 vac input without any strapping; brownout protection to 90/180 vac
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.120 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.680 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.290 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Pacer special
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 1st alternate operating power rqmt and 130.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
198.0 ac pounds per hour dry 2nd alternate operating power rqmt and 265.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts 1st power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
5.0 dc volts 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st alternate operating power rqmt and 1000.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd alternate operating power rqmt and 1000.0 hertz 2nd alternate operating power rqmt
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Remote error sensing capability and circuit overload protection device
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
3.0 dc amperes single power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
8.0 dc amperes 2nd power output