Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Pre Wire Wound Variable Resistor				
			 
			
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical servo mounted					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
					 
					
						Pilot Diameter:
					
					
						Between 0.6250 inches and 0.6260 inches 					
				 
							
					
						MRC:
						The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
					 
					
						Pilot Length:
					
					
						Between 0.0570 inches and 0.0620 inches 					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.073 inches 					
				 
							
					
					
						Undercut Diameter:
					
					
						Between 0.865 inches and 0.875 inches 					
				 
							
					
					
						Undercut Width:
					
					
						Between 0.0630 inches and 0.0700 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						0.880 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						Between 0.483 inches and 0.517 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.573 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						1.083 inches 					
				 
							
					
					
						Mounting Lip Diameter:
					
					
						Between 0.8650 inches and 0.8750 inches 					
				 
							
					
					
						Mounting Lip Depth:
					
					
						Between 0.0570 inches and 0.0620 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round					
				 
							
					
						MRC:
						The location of the contact arm when there is no electrical continuity between the moving contact and the resistive element.AEEZ
					 
					
						Contact Arm Electrical Off Position:
					
					
						Fully cw					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
					 
					
						Effective Electrical Rotation In Deg Angular Rotation:
					
					
						Between 359.0 and 360.0 					
				 
							
					
						MRC:
						The maximum amount of turning force required to initiate the actuator movement.AEFK
					 
					
						Maximum Starting Torque:
					
					
						0.40 inch-ounces					
				 
							
					
						MRC:
						The maximum amount of force requred to maintain actuator movement.AEFL
					 
					
						Maximum Running Torque:
					
					
						0.30 inch-ounces					
				 
							
					
						MRC:
						The maximum amount of turning force that can be applied through the operating shaft with0ut damage to the stops.AEFM
					 
					
						Maximum Stop Torque:
					
					
						130.00 inch-ounces					
				 
							
					
						MRC:
						The total axial excursion of the shaft measured at the end of the shaft with a specified axial load applied alternately in the opposite directions.AEFY
					 
					
						Shaft End Play:
					
					
						0.002 inches					
				 
							
					
						MRC:
						The maximum difference of shaft position that occurs when the shaft is moved to the same actual output ratio point from opposite directions,expressed in degree angular rotation.AEGD
					 
					
						Mechanical Backlash In Deg Angular Rotation:
					
					
						0.1					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						Lower adjacent side single row					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Clamp ring					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						10.0 kilohms single section					
				 
							
					
						MRC:
						The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
					 
					
						Rotary Actuator Travel In Angular Deg:
					
					
						Between 3600.0 and 3630.0 					
				 
							
					
						MRC:
						The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
					 
					
						Function Conformity Tolerance Per Section:
					
					
						-0.05/+0.05 single section					
				 
							
					
						MRC:
						The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
					
					
						125.0 single section					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
					 
					
						Power Dissipation Rating Per Section In Watts:
					
					
						2.0 free air single section					
				 
							
					
						MRC:
						The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
					 
					
						Function Conformity Per Section:
					
					
						Single section independent linearity					
				 
							
					
						MRC:
						The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
					 
					
						Fixed Tap Quantity Per Section:
					
					
						1 single section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-1.0/+1.0 single section					
				 
							
					
						MRC:
						The feature that controls the actuator travel.CRSX
					 
					
						Actuator Travel Control Feature:
					
					
						Clutch					
				 
							
					
						MRC:
						Indicates the location of a tap relative to the counterclockwise terminal per section,expressed in ohms.CSBW
					 
					
						Tap Location From Ccw Terminal Per Section In Ohms:
					
					
						5000.0 single section					
				 
							
					
						MRC:
						The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
					 
					
						Function Characteristic Per Section:
					
					
						Single section linear					
				 
							
					
						MRC:
						The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
					
					
						40.0 single section					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						10001-2075046 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						3 solder stud