Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
3326a-003-c01-909
Informationen zum Teil
Opt 003: rear terminal outputs, opt c01: rear panel sync, opt 909 rack flang and handel kit: operating modes: two-channel, two-phase, two-tone, and pulse. Modulation range 0 to 5khz, waveforms: sine, square or pulse. 0 to 100pct modulation.
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electrical Frequency Synthesizer
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
497.8 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
177.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
425.5 millimeters
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
An/gsm-370
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
0.0 megahertz 1st output channel err-100 and 13.0 megahertz 1st output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
0.0 megahertz 2nd output channel err-100 and 13.0 megahertz 2nd output channel err-100
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 single voltage and 66.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
110.0 single voltage and 220.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single