Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
3424-0000-0000
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Electric Heat Treating Furnace
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
22.000 inches and 16.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
34.000 inches and 22.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
24.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
36.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
2400.0 degrees fahrenheit
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
8.000 inches and 6.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+1000.0/+2400.0 degrees fahrenheit
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
18.000 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Any acceptable
MRC:
Indicates the type of temperature control device provided.AZFX
Tempurature Control Device Type:
Automatic
MRC:
An indication of whether or not a tilting hearth is included.CFSQ
Tilting Hearth:
Not included
MRC:
An indication of whether or not a work holding basket is included.CFSR
Work Holding Basket:
Included
MRC:
Indicates the location and number of doors and/or openings.CFSS
Door/opening Location And Quantity:
Door in end, 1
MRC:
An indication of whether or not a counterweight(s) is included.CFST
Counterweight:
Not included
MRC:
An indication of whether or not equipment for a flame curtain is included.CFSW
Equipment For Flame Curtain:
Not included
MRC:
The means used to operate the access.CGSP
Access Operation Method:
Manually operated door
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
A numeric value which represents a positive whole value without regard to any unit of measure.NMBR
Quantity:
1 and 2