Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
3431-1320-3063
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Arc Welding Machine
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Skid
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Lead, electrode, 50 ft w/electrode holder, 1; lead, work, 50 ft w/ground clamp, 1
MRC:
The speed at which an item has been tested and rated to perform without damage or failure of the rotating components,expressed in revolutions per minute.AMZE
Rotational Speed Rating In Rpm:
3600.0
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
20.0
MRC:
The rated power output for which the item is designed.ANLH
Power Output Rating:
1.5 kilowatts
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Ac
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
115.0
MRC:
The current the item will permit to pass,expressed in amperes.ANYP
Output Current Rating In Amps:
300.0
MRC:
Indicates the design type of the item.APGF
Design Type:
Generator
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
60.0 hertz
MRC:
The source of power which drives the item.ATJK
Power Source:
Gasoline engine
MRC:
The name of the manufacturer of the engine furnished.ATJL
Engine Manufacturer Name:
Mil std
MRC:
The number used by the manufacturer for identifying the engine.AYHQ
Engine Manufacturer Identifying Number:
Model no. 4a084
MRC:
The number of output alternating current phases.BFLS
Output Phase:
Single
MRC:
Indicates the type of current of the arc.CDRR
Arc Current Type:
Dc
MRC:
The minimum current which must be maintained at a specified voltage.CDRS
Minimum Current At Specificationified Voltage:
50 amp at 30v
MRC:
The maximum current which must not be exceeded at a specified voltage.CDRT
Maximum Current At Specificationified Voltage:
400 amp at 30v
MRC:
Indicates the type of operator for which the item is designed.CDRW
Operator Type For Which Designed:
Single
MRC:
An indication of whether or not a remote control design is included.CDRY
Remote Control Design:
Not included
MRC:
An indication of whether or not an auxiliary power output design is included.CDRZ
Auxiliary Power Output Design:
Included