Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
352250026934
Entmilitarisierung:
Yes - DEMIL/MLI
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical w/rear terminals
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.180 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.660 inches
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.20 and 1.30 and 1.45
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The mathematical relationship of power available at the load before and after addition of the item to the circuit,set to its lowest value of attenuation,expressed in maximum decibels.ASYC
Insertion Loss At Minimum Attenuation In Maximum Decibels:
0.3
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0/+9.0
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Stepped
MRC:
The number of intervals at which the item can be set.ASYG
Step Position Quantity:
9
MRC:
The amount of attenuation between adjacent steps,expressed in decibels.ASYH
Attenuation Per Step In Decibels:
1.0
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 hertz and 12.400 gigahertz
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-0.30/+0.30
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 knob
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
50.0 input-output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 connector, coaxial, female