Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Entmilitarisierung:
Yes - DEMIL/MLI
Informationen zum Teil
Hy-pot tester; t.O.33a1-4-95-1/-11
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Insulation Breakdown Test Set
MRC:
Indicates the type of termination provided on the wire.ABCC
Wire Termination Type:
Clip
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
14.560 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
11.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts or 230.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 47.0 hertz and 63.0 hertz
MRC:
A measurement of the longest dimension of a wire lead.AFSC
Wire Lead Length:
60.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Common test equipment
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Bench or rack
MRC:
Indicates the type of output current whether alternating,direct,or both.ANPN
Output Current Type:
Ac and dc
MRC:
An indication of the type of meter.ANTH
Meter Type:
Ammeter and voltmeter
MRC:
The number of meters provided.ANTJ
Meter Quantity:
2
MRC:
An indication of the scale range.APSK
Scale Range:
+0.0/+12.0 milliamps and +0.0/+6.0 kilovolts
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
5.000 kilovolts and 6.000 kilovolts
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
12.000 milliamperes and 5.000 milliamperes
MRC:
Indicates the type of indicator used to show a leakage condition.AQYK
Leakage Indicator Type:
Meter
MRC:
The number of test leads provided with the item.AQYL
Test Lead Quantity:
2
MRC:
The device provided to protect the circuit from an electrical overload condition.AQYM
Circuit Overload Protection Device:
Fuse
MRC:
The number of alternating current phases.FAAZ
Phase:
Single