Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Hy-pot tester; t.O.33a1-4-95-1/-11
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Insulation Breakdown Test Set				
			 
			
							
										
					
						MRC:
						Indicates the type of termination provided on the wire.ABCC
					 
					
						Wire Termination Type:
					
					
						Clip					
				 
							
					
						MRC:
						An overall measurement between specified points of an item,in distinction from height.ABFY
					 
					
						Overall Depth:
					
					
						14.560 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						11.000 inches 					
				 
							
					
						MRC:
						The value,or range of values,of root mean square potential for which the item is rated.ACYN
					 
					
						Ac Voltage Rating:
					
					
						115.0 volts  or 230.0 volts 					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
					 
					
						Frequency Rating:
					
					
						Between 47.0 hertz and 63.0 hertz 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a wire lead.AFSC
					 
					
						Wire Lead Length:
					
					
						60.000 inches 					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						Common test equipment					
				 
							
					
						MRC:
						An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
					 
					
						Internal Battery Accommodation:
					
					
						Not included					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Bench or rack					
				 
							
					
						MRC:
						Indicates the type of output current whether alternating,direct,or both.ANPN
					 
					
						Output Current Type:
					
					
						Ac and dc					
				 
							
					
						MRC:
						An indication of the type of meter.ANTH
					 
					
						Meter Type:
					
					
						Ammeter and voltmeter					
				 
							
					
						MRC:
						The number of meters provided.ANTJ
					 
					
						Meter Quantity:
					
					
						2					
				 
							
					
						MRC:
						An indication of the scale range.APSK
					 
					
						Scale Range:
					
					
						+0.0/+12.0 milliamps and +0.0/+6.0 kilovolts					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
					 
					
						Output Frequency Rating:
					
					
						Between 50.0 hertz and 60.0 hertz 					
				 
							
					
						MRC:
						The output voltage rating at which the item is designed to operate.AQYB
					 
					
						Output Voltage Rating:
					
					
						5.000 kilovolts  and 6.000 kilovolts 					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.AQYD
					 
					
						Output Current Rating:
					
					
						12.000 milliamperes  and 5.000 milliamperes 					
				 
							
					
						MRC:
						Indicates the type of indicator used to show a leakage condition.AQYK
					 
					
						Leakage Indicator Type:
					
					
						Meter					
				 
							
					
						MRC:
						The number of test leads provided with the item.AQYL
					 
					
						Test Lead Quantity:
					
					
						2					
				 
							
					
						MRC:
						The device provided to protect the circuit from an electrical overload condition.AQYM
					 
					
						Circuit Overload Protection Device:
					
					
						Fuse					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single