Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
					
						Entmilitarisierung:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Informationen zum Teil
						Mirocircuit,  linear,  12-bit 100ksps a/d converter,  plastic encapsulated surface mount
					 
				 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Linear Microcircuit				
			 
			
							
										
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						Between 0.697 inches and 0.713 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						Between 0.291 inches and 0.299 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						Between 0.075 inches and 0.100 inches 					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended by an item.AEHX
					 
					
						Maximum Power Dissipation Rating:
					
					
						575.0 milliwatts					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+125.0 degrees celsius					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						C-17a aircraft					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Electrostatic sensitive					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
					 
					
						Inclosure Material:
					
					
						Plastic					
				 
							
					
						MRC:
						Indicates the physical configuration of the inclosure.CQSZ
					 
					
						Inclosure Configuration:
					
					
						Dual-in-line					
				 
							
					
						MRC:
						The basic purpose and number of functions of the device,modified by its intended use.CSSL
					 
					
						Design Function And Quantity:
					
					
						1 converter,  analog to digital					
				 
							
					
						MRC:
						The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
					 
					
						Current Rating Per Characteristic:
					
					
						14.00 milliamperes reverse current,  dc absolute					
				 
							
					
						MRC:
						The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
					 
					
						Voltage Rating And Type Per Characteristic:
					
					
						11.4 volts  power source and 16.5 volts  power source					
				 
							
					
						MRC:
						Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
					 
					
						Special Test Features:
					
					
						Upscreening testing consisting of exteneded temperature range testing of pem from -55 to 125 degrees celsius					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						89954-356a1407 drawing (this is the basic governing drawing,  such as a contractor drawing,  original equipment manufacturer drawing,  etc.;  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						28 gullwing