Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Refrigeration Compressor				
			 
			
										
					
						MRC:
						The media the machine is designed to compress.AAXK
					 
					
						Gas For Which Designed:
					
					
						Refrigerant r-22					
				 
							
					
						MRC:
						The gage pressure of gas delivered by the last stage of compression.  referred to as condensing pressure for refrigeration compressors.AAXM
					 
					
						Discharge Pressure:
					
					
						450.000 pounds per square inch gage					
				 
							
					
						MRC:
						The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
					 
					
						Cooling System Design:
					
					
						Single					
				 
							
					
						MRC:
						The cooling medium used to maintain the required operating temperature of the compressor.AAXR
					 
					
						Compressor Cooling Medium:
					
					
						Air and fresh water					
				 
							
					
						MRC:
						The reciprocating compressor design as determined by the mechanical action by which compression takes place in the cylinder/s/ of the compressor.AAXY
					 
					
						Reciprocating Compressor Design:
					
					
						Compound acting					
				 
							
					
						MRC:
						The number of cylinders incorporated in the item.AAXZ
					 
					
						Cylinder Quantity:
					
					
						8					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the angular arrangement of the cylinders.AAYA
					 
					
						Cylinder Arrangement Style:
					
					
						Semi-radial design					
				 
							
					
						MRC:
						The number of stages incorporated in the item.AAYD
					 
					
						Stage Quantity:
					
					
						2					
				 
							
					
						MRC:
						The pressure of the gas after it has passed through the evaporator and prior to its compression within the item.AAYF
					 
					
						Suction Pressure:
					
					
						330.0 pounds per square inch					
				 
							
					
						MRC:
						The number of intake connections included on the item.AAYT
					 
					
						Intake Connection Quantity:
					
					
						1					
				 
							
					
						MRC:
						The number of discharge connections included on the item.AAYV
					 
					
						Discharge Connection Quantity:
					
					
						1