Teilenummer
					Entmilitarisierung
					Lagerfähigkeit
					UOM
					NIIN
				 
				
					
						Teilenummer:
						37675675-002					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Nationale Bestandsnummer:
				
				
			 
			
				
					TXT
				
				
					Beschreibung:
				
				
					Electrical Solenoid				
			 
			
										
					
						MRC:
						A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
					 
					
						Thread Class:
					
					
						2a mounting facility bushing					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
					 
					
						Thread Direction:
					
					
						Right-hand mounting facility bushing					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical frame					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						1.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						1.120 inches 					
				 
							
					
						MRC:
						The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
					 
					
						Maximum Operating Temp:
					
					
						40.0 degrees celsius					
				 
							
					
						MRC:
						The measurement of the distance that the actuator protrudes from the body.AFGK
					 
					
						Actuator Length:
					
					
						0.936 inches 					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the actuator,and terminates at the circumference.AFUR
					 
					
						Actuator Diameter:
					
					
						0.437 inches 					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Fully enclosed					
				 
							
					
						MRC:
						The number of magnetic coils provided.APAF
					 
					
						Magnetic Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						A measurement of the opposition to the flow of direct or alternating current.APCC
					 
					
						Electrical Resistance:
					
					
						145.00 ohms 					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						End opposite actuator					
				 
							
					
						MRC:
						The value of electrical energy for which the item is rated.ARQE
					 
					
						Electric Power Rating:
					
					
						4.0 watts 					
				 
							
					
						MRC:
						The voltage rating at which the item is designed to operate,expressed in volts.ASXH
					 
					
						Voltage Rating In Volts:
					
					
						24.0 dc 					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded bushing					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						24 mounting facility bushing					
				 
							
					
						MRC:
						The movement of the actuator when force is applied.CNXT
					 
					
						Actuator Stroke Type:
					
					
						Pull					
				 
							
					
						MRC:
						The amount of linear force delivered.CNXW
					 
					
						Linear Force Delivered:
					
					
						3.00 ounces					
				 
							
					
						MRC:
						Indicates the type of means provided for connection of the power takeoff.CNXX
					 
					
						Power Takeoff Connection Type:
					
					
						Slotted-drilled					
				 
							
					
						MRC:
						The maximum linear travel from the de-energized to the energized position.CNYD
					 
					
						Energizing Stroke Maximum Length:
					
					
						0.438 inches					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.750 inches mounting facility bushing					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Uns mounting facility bushing					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 wire lead