Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Motor Controller
MRC:
The different speeds at which the item may be operated.ABBB
Speed Adjustments:
Five speed
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
60.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
10.500 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Semiautomatic
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
3
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Eight 7/16 in. Diameter mtg holes arranged 2 ea on top and bottom and 2 ea on sides; top and bottom holes spaced 15 in. C to c and 1-1/2 in. From front surface of frame iron; side holes spaced 71-3/4 in. C to c on ea side and 3 in. From bottom and 1-1/4 in. From top
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Reduced
MRC:
The means used to reduce the electrical voltage.ANCP
Voltage Reduction Method:
Resistor
MRC:
The means used to restore the item to its full voltage.ANCQ
Full Voltage Restoring Method:
Current limit acceleration
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
50.000
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
230.0 dc
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Overload and undervoltage
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
50.0 degrees celsius
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Reversible and accessory location external and circuit protection fuse
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
5 size