Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
38-3772-8000
Informationen zum Teil
Optical control type with two scales top scale p0.0/p0.075, bottom scale p0.0/p0.0375
NSN
Nationale Bestandsnummer:
TXT
Beschreibung:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
3
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Connector, receptacle and stud
MRC:
The standard of valuation as represented by the inscription.ABWC
Scale Unit Of Measure Inscription:
Hertz
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
50
MRC:
A measurement of the longest dimension of a mounting flange, in distinction from width.ADMG
Mounting Flange Length:
3.280 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
3.130 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The hue or tint of the light emitted from that portion of the item which surrounds the inscription on the item.AETT
Inscription Background Color:
White
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Instrument landing sysgem (mark1b)
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 4-40 thd studs on 2.250in by 2.250 in mtg centers
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+100.0 microamperes
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0 to 100.0 microamperes
MRC:
An indication of the direction of the meter movement reading range.APGT
Meter Movement Range Direction:
Left to right
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Semiflush
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.790 inches
MRC:
A measurement between the mounting flange and the face of the item, in distinction from height.APTN
Meter Depth To Mounting Flange:
1.910 inches