Teilenummer
Entmilitarisierung
Lagerfähigkeit
UOM
NIIN
Teilenummer:
388-07
Entmilitarisierung:
Yes - DEMIL/MLI
Lagerfähigkeit:
Maßeinheit:
NIIN:
015234569

Informationen zum Teil
If to tape/baseband converter

NSN
Nationale Bestandsnummer:
5895-01-523-4569 5895015234569
TXT
Beschreibung:
Signal Data Converter
INC
INC
Artikelname-Code:
00441
INC
COM
Beachtung:
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+40.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 megahertz 4th input channel err-100 and 250.0 megahertz 4th input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
160.0 megahertz 3rd input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.1 megahertz 1st output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
4.3 megahertz 4th output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 megahertz 5th input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
70.0 megahertz 2nd input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
2.2 megahertz 2nd output channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
21.4 megahertz 1st input channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
3.2 megahertz 3rd output channel err-100
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Stepped
MRC:
The frequency of each step.BHTF
Individual Step Frequency:
5000.0 kilohertz and 1.0 kilohertz
MRC:
The amount of allowable variation relative to a specified frequency level,expressed in decibels.BHTG
Variation Frequency Rating In Decibels:
-0.5 and 0.5
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
14.0
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st input channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd input channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd input channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
4th input channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
4th output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
5th input channel pulse err-100
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Connector, plug rear
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
9 connector, plug external
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Rs-233 control; group delay equalization; compact half-rack package; input level range negative 70 dbm to 0 dbm; power 90-240 vac; 47-420 hz; 45 watts max; weight 8 lb; warran type 1 year
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to convert if to tape and record a/d signals